Vacusill 2HV

The VACUSILL® 2HV high vacuum regulators are a high-vacuum, high-flow medical suction unit powered by a vacuum source, which allows vacuum regulation with outstanding stability and precision. Compatible with MRI.

DOWNLOADS:

Categories: ,

Description

  • ON/OFF switch for quick opening and closing, with pressure relief valve overflow when vacuum gauges are in OFF mode.
  • Safety relief valve for excess vacuum.
  • Water trap with overflow safety valve and particle filter.
  • Whitworth G1/4” F inlet thread.
  • Range: 0-100 kPa / 0-750 mmHg.
  • Accuracy: ± 5%.
  • Flow: 100 L/min.
  • Available with fittings: BS, NF, DIN and SS. Consult availability of other connections.
  • Available with SafeyTrap water trap with overflow safety system and high efficiency particle filter or viral hydrophobic bacterial filter.
  • Possibility of being supplied with PC/PSU collection jar, PC1/PSU1 – PC2/PSU2 – PC4/PSU4 (consult more details about capacity and scale in the suction jar section), rolling support and rail coupling system.
  • Materials: body in ABS-PC, O-rings in NBR and silicone. Vacuum gauge cover in PC. Whitworth thread G1/4” F (without fitting) in stainless steel. Latex-free.
  • Dimensions: 240 mm x 86 mm x 86 mm.
  • Weight: 310 g.

Optional accessories: consult brochure.

Contact HERSILL






    HERSILL S.L. is Responsible for the processing of the user's personal data and informs you that these data will be processed in accordante with the provisions of Regulation (EU) 2016/679 of 27 April 2016 (GDPR), so you are provided with the following processing information:
    End of treatment: maintaining a business relationship and sending communications about our products and services.
    Data retention criteria: they shall be retained for as long as there is a mutual interest in maintaining the purpose of the processing and when it is no longer necessary of that purpose, they shall be deleted with appropriate security measures to ensure the pseudonymisation of the data or the total destruction of the same.
    Data communication: The data will not be communicated to third parties, except for legal obligations.
    Legitimation of treatment: The consent of the interested party.
    Rights that assist the user: Right to withdraw consent at any time. Right of access, rectification, portability and deletion of your data and the limitation or opposition to their processing. Right to lodge a complaint with the Supervisory Authority (agpd.es) if you consider that the treatment does not comply with the regulations in force.
    Contact information to exercise your rights Puerto de Navacerrada, 3, Polígono Industrial Las Nieves - 28935 Mostoles (Madrid) Spain

    SUBSCRIBE TO

    OUR NEWSLETTER